Power and energy in circuits: P = VI, P = I²R, E = Pt and E = QV
By Engr. Mehmood Kakar · Updated
Quick answer
Use P = V × I when you know pd and current, P = I² × R when you know current and resistance, then E = P × t for the energy transferred. E = Q × V gives the same energy from charge and pd. Power is in watts (joules per second), so time must be in seconds to get energy in joules.
The four equations
| Equation | In words | Units |
|---|---|---|
| P = V I | power = potential difference × current | W = V × A |
| P = I² R | power = current² × resistance | W = A² × Ω |
| E = P t | energy transferred = power × time | J = W × s |
| E = Q V | energy transferred = charge flow × potential difference | J = C × V |
All four are on the AQA equation sheet. You still have to choose the right one and rearrange it.
Which equation to use
- Given pd and current, finding power → P = VI
- Given current and resistance, finding power → P = I²R
- Given power and time, finding energy → E = Pt
- Given charge and pd, finding energy → E = QV
If a question gives pd and resistance but no current, find the current first with I = V ÷ R, then use either power equation.
P = VI worked
A kettle is rated 2.3 kW and runs on the 230 V mains. Calculate the current.
- Convert: P = 2.3 kW = 2300 W
- Rearrange: I = P ÷ V
- I = 2300 ÷ 230
- I = 10 A
P = I²R worked
A current of 3.0 A flows through a 20 Ω resistor. Calculate the power.
- P = I² × R = 3.0² × 20
- Square the current first: 3.0² = 9.0
- P = 9.0 × 20
- P = 180 W
A heater has a resistance of 25 Ω and a power of 100 W. Calculate the current. (Higher)
- Rearrange: I² = P ÷ R = 100 ÷ 25 = 4.0
- Square root: I = √4.0
- I = 2.0 A
Energy: E = Pt and E = QV
How much energy does the 2.3 kW kettle transfer in 3 minutes?
- Convert: P = 2300 W, t = 3 × 60 = 180 s
- E = P × t = 2300 × 180
- E = 414 000 J (414 kJ)
The two energy equations agree. A 12 V lamp taking 2.0 A for 5 minutes:
Find the energy transferred by a 12 V, 2.0 A lamp in 5 minutes, two ways.
- t = 5 × 60 = 300 s
- Way 1: P = VI = 12 × 2.0 = 24 W, so E = Pt = 24 × 300 = 7200 J
- Way 2: Q = It = 2.0 × 300 = 600 C, so E = QV = 600 × 12 = 7200 J
- E = 7200 J either way
Why the National Grid uses high pd
Power stations send electricity across the country at very high pd. For the same power, P = VI means a higher pd needs a smaller current. The power wasted heating the cables is P = I²R, so cutting the current cuts that waste sharply: halve the current and the heating loss falls to a quarter.
Step-up transformers raise the pd before the cables, and step-down transformers lower it to 230 V for homes. The transformer guide has the turns-ratio calculations.
Common mistakes
- Minutes or hours in E = Pt. Convert to seconds for an answer in joules.
- Kilowatts left as kW. 2.3 kW is 2300 W.
- Squaring the wrong thing. In P = I²R only the current is squared.
- Missing the square root. When finding current from P = I²R, the last step is √.
Practice
1. A hairdryer takes 5.0 A from the 230 V mains. Calculate its power.
P = V × I = 230 × 5.0 → P = 1150 W
2. A 60 W lamp is on for 2 hours. How much energy does it transfer?
t = 2 × 3600 = 7200 s → E = P × t = 60 × 7200 → E = 432 000 J
3. 150 C of charge flows through a component with a pd of 9.0 V across it. How much energy is transferred?
E = Q × V = 150 × 9.0 → E = 1350 J
4. A 0.50 A current flows through a 40 Ω resistor. Calculate the power.
P = I² × R = 0.50² × 40 = 0.25 × 40 → P = 10 W
Frequently asked questions
What is the difference between P = VI and P = I²R?
They give the same power. P = VI uses the potential difference and current. P = I²R uses the current and resistance; it comes from putting V = IR into P = VI. Pick the one that matches the quantities the question gives you.
What unit is electrical power measured in?
Watts (W). One watt is one joule of energy transferred per second. 1 kW = 1000 W.
How do you calculate the energy used by an appliance?
Multiply its power in watts by the time in seconds: E = P × t. The answer is in joules. If you know the charge instead, use E = Q × V.
Why is electricity transmitted at high voltage?
For the same power, a higher pd means a smaller current (P = VI). The energy wasted heating the cables depends on I²R, so a smaller current wastes much less energy. Step-up transformers raise the pd for the cables and step-down transformers lower it for homes.